PV fed ZSI based DVR Topology with ANFIS Control Strategy

SUDHA RAMASAMY, Sudheer Kasa

Abstract


The performance of present complex power system suffers with sudden current and voltage variations. The present model uses renewable source for Z - Source Inverter fed Dynamic Voltage Restorer (PV-ZSI-DVR). The proposed DVR topology dynamically compensates voltage interruptions, swell and sag to maintain the required level of voltage to the load. Here conventional DVR topology performance has been extended by incorporating the Hybrid Control technique ANFIS .The model presents the utilization of solar power for DVR operation in compensating the different voltage fluctuations. The performance of PV-ZSI- DVR with different control strategies have been compared in MATLAB/SIMULINK environment.

Keywords


FACTS; DVR; ZSI; PID, FUZZY Controllers; Neural Networks; Renewable Sources.

Full Text:

PDF

References


A.El Mofty, K.Youssef, “Industrial power quality problemsâ€, Alexandria Electricity Company, Alexandria, Egypt, June 2007, pp.18-21

Il-Yop Chung, Dong-Jun Won, Sang-Young Park, Seung-Il Moon, Jong-Keun Park, “The DC link energy control method in dynamic voltage restorer systemâ€, INT J Elec Power (25), 2003, pp.525-531

C.Fitzer, M.Barnes, Peter Green, “Voltage sag detection technique for a dynamic voltage restorerâ€, IEEE T Ind Appl, Vol.40, No.1 Jan/Feb. 2004, pp.203- 212.

Alexander Domijan, Alejandro Montenegro, Albert J. F. Keri, Kenneth E. Mattern, “Custom Power Devices: An Interaction Studyâ€, IEEE T Power Syst, Vol.20, No.2, May 2005, pp.1111-1118.

Dong-Myung Lee, Thomas G. Habetler, Ronald G. Harley, Joe Rostron, Tom Keister, “A voltage sag supporter utilizing a PWM switched autotransformerâ€, IEEE Power Electronics Specialists Conference,2004 Aachen, Germany, pp.4244 – 4250

IEEE and Standards, "IEEE Std 1159-1995, IEEE Recommended practice for monitoring electric power quality," Standard, June, 1995.

V.K.Ramachandaramurthy, C.Fitzer, A.Arulampalam, C.Zhan, M.Barnes, N.Jenkins, “Control of a battery supported dynamic voltage restorer†, IEE P-Gener Transm D ,Vol 149 No. 5,Sep 2002,Pp 533-542.

Loc Nguyen Khanh,Jae-Jin Seo, Yun-Seong Kim, and Dong-Jun Won, “Power-Management Strategies for a Grid-Connected PV-FC Hybrid Systemâ€, IEEE T Power Deliver, Vol. 25, No. 3, July 2010,Pp 1874-1882

Bijan Rahmani, Weixing Li, Guihua Liu, “An Advanced Universal Power Quality Conditioning System and MPPT method for grid integration of photovoltaic systemsâ€, INT J Elec Power, Volume 69, July 2015, pp 76-84.

Mukhtiar Singh, Ambrish Chandra and Rajiv K. Varma, “Grid Interconnection of Renewable Energy Sources at the Distribution Level with Power-Quality Improvement Featuresâ€, IEEE T Power Deliver, vol. 26, no. 1, pp 307-315 Jan 2011

J. M. Carrasco, L. G. Franquelo, J. T. Bialasiewicz, E. Galván, R. C. P. Guisado, M. Ã. M. Prats, J. I. León, and N. M.Alfonso,“Power electronic systems for the grid integration of renewable energy sources: A surveyâ€, IEEE Trans. Ind. Electron., vol. 53, no. 4, pp. 1002–1016, Aug. 2006.

Fang zheng pengo "Z-Source inverter" IEEE T Ind Appl,2003., vol. 39, no. 2.,pp:504-510.

D. M. Vilathagamuwa, C. J. Gajanayake, P.c. Loh, and yw. Li., “Voltage Sag Compensation with Z- Source inverter Based Dynamic Voltage Restorerâ€, IEEE IAS'06,pp. 2242-2248.

Agileswari K. Ramasamy; Rengan Krishnan Iyer; Dr. Vigna K Ramachandramurthy, Dr.R.N.Mukerjee, “Dynamic Voltage Restorer for voltage sag compensationâ€, Conference on Power Electronics and Drive Systems, Vol.2, Nov. 2005, pp 1289 – 1294.

Changjiang Zhan, Atputharajah Arulampalam, Nicholas Jenkins, “Four-wire Dynamic Voltage Restorer based on a three-dimensional voltage Space Vector PWM algorithmâ€, IEEE T Power Electr, Vol.18, No.4, July 2003, pp 1093 -1102.

Sudheer kasa, Sudha Ramasamy, Prabhu Ramanathan, “Hybrid Fuzzy-ZN PID control based Grid Interfaced distribution level Renewable Energy Source with Power Qualityâ€, ICCPCT,IEEE, pp.1-7, Mar 2015

Sudheer kasa,Sudha Ramasamy, Prabhu Ramanathan and D.P.Kothari, “Effective Grid Interfaced Renewable Sources with Power Quality Improvement using Dynamic Active Power Filterâ€, INT J Elec Power,2016. DOI: 10.1016/j.ijepes.2016.03.002.

C. Elmas, O.Ustun, and H.Sayan, “A neuro-fuzzy controller for speedcontrol of a permanent magnet synchronous motor driveâ€, Expert Syst Appl, vol.34, no.1.,2008.

J.-S.Jang, “ANFIS: adaptive network based fuzzy inference systemâ€, IEEE Trans. Syst., Man Cybern.Vol.23,No.3, 1993,pp.665–685.

L.S.Czarnecki, “Power related phenomena in three-phase unbalanced systemsâ€, IEEE Trans. Power Del,1995.Vol.10,No.3,pp.1168–1176.




DOI (PDF): https://doi.org/10.20508/ijrer.v6i3.3853.g6865

Refbacks

  • There are currently no refbacks.


Online ISSN: 1309-0127

Publisher: Gazi University

IJRER is cited in SCOPUS, EBSCO, WEB of SCIENCE (Clarivate Analytics);

IJRER has been cited in Emerging Sources Citation Index from 2016 in web of science.

WEB of SCIENCE in 2025; 

h=35,

Average citation per item=6.59

Last three Years Impact Factor=(1947+1753+1586)/(146+201+78)=5286/425=12.43

Category Quartile:Q4